KoKo Lengend
SPECIFICATIONS
Tests:
FVC, SVC, Pre-Post BD
Parameters Measured:
Expiratory:
FVC, FEV.5, FEV.5/FVC%, FEV1, FEV1/FVC%, FEV3, FEV3/FVC%, FEV6, FEV6/FVC%, FEV1/FEV6%, +PEFR, FEF25%, FEF50%, FEF75%, FEF25-75%, FEF.2-1.2, FEF75-85%, Tpeak(mSec), Vext%, Vext(L), MET(S), Texp(S), Veot(L)
Inspiratory:
FIVC, FIV.5, FIV.5/FIVC, FIV1/FIVC, FIV3, FIV3/FIVC, PIFR, FIF50%, FIF25-75%, FIF.2-1.2, FIF50/FEF50, MIT(S), Tinsp(S)
Pneumotach:
Flexible Variable Orifice Pneumotachometer
Filter Requirement:
KoKoMoe (model #810000 or 819000)
Power Equipment:
Supplied external 100-240 VAC Switching Power Supply / Recharger, 12 VDC Output, 2.5 Amp.; Rechargeable internal NiMH battery.
Accuracy:
< +/- 3% or 100 ml, whichever is greater
Reproducibility:
<+/- 0.5%
Volume Range:
+/- 16L
Flow Range:
+/- 16 L/s
Resistance:
< 1.5 cmH20/L/sec when tested with KoKoMoe filter
Memory Storage:
Estimated 1200 test series per 16 MB Card and complete flash memory
Software Compatibility KoKo PFT Spirometry Software version 4.5 or higher; operating on for Download: Windows 2000, XP or higher
Predicted Sets:
Hankinson (NHANES III), Crapo 1981, Polgar (Pediatrics), ERS 93 (ECCS), Perriera (Brazil),Gore (Australia)
Interpretation Algorithm:
McKay (ATS / ARRD 1991)
Reports:
Formats for both Internal and External Printers:
FVC Standard Best, FVC Pre-Post Best, FVC Complete + SVC Best, FVC Complete + SVC Pre-Post Best, FVC V/T Full Size, FVC Pre-Post + V/T Full Size, FVC Standard Best 3, FVC Pre-Post Best 3
Incentive Graphics:
Photo-realistic Color Candles
Connectivity:
Built-in internal Internet-ready Modem (optional); Built-in Ethernet port for automatic network connection (optional); Downloadable to KoKo PFT Software via built-in USB port; Uploadable patient demographics from KoKoPFT via built-in USB port.
Printing:
Internal thermal printer and external parallel printer support (HP PCL3 format)
Dimensions:
23.5 x 25.4 x 7.0 cm; 9.25 x 10.0 x 2.75 inches
Weight:
1.6 kg; 3.6 lbs.
Construction:
High-impact Polycarbonate
Operating Environment:
10 - 40°C; 0 – 80% relative humidity non-condensing at temperatures to 31°C
Safety:
Use only supplied Class II Power adapter; Ordinary equipment (not protected against harmful ingress of moisture); Not suitable for use with flammable anesthetics; Suitable for continuous use
EMC Rating:
Radiation and conducted emissions and immunity per EN 60601-1-2
Performance standards:
ATS 1994 – properly measures all 26 flow-time waveforms; ERS; BTS; NIOSH; ACOEM
Quality standards:
Quality System Regulations - FDA QSR, ISO 9002, EN 46002
European Directives - MDD 93/42/EEC
Product Standards - EN 60601-1, 60601-1-1, 60601-1-2, 60601-1-4